CR Phantom | Computed Radiography
  • T-target (brass)
    Laser beam jitter, MTF check, Blooming (Flare)

  • Duplex wire-type IQI 15D (hi-res)
    Basic Spatial Resolution (Unsharpness)

  • BAM snail
    Central beam alignment

  • Line pair IQI type 53-b
    Line pair resolution

  • Measuring points
    Shading correction

  • Cassette positioning locator
    Positioning of cassette (imaging plate)

  • Homogeneous strip (aluminium)
    Scanner slippage, scanner shading

  • Lucite plate
    Carrier plate

  • cm/inch ruler
    Linearity check

  • Contrast sensitivity gauge
    Contrast sensitivity check

CR Phantom

CR Phantom

Test specimen for easy qualification of Computed Radiography systems according to the latest standards (ISO 16371-1, ASTM E 2445)

Icon

Ultra-compact

With only 20 cm height and 27.5 cm width the smallest CR Phantom on the market

Icon

Ready to use

Including report template and test procedure – register here to get your free copy

Icon

Well protected

A lined wooden case protects the CR Phantom during storage and transport

The CR Phantom can test all the important performance characteristics of a CR scanner system including basic spatial resolution (unsharpness), contrast, MTF, laser beam jitter, scanner slipping and scanner shading. These tests are described in detail in the ISO 16371-1 and ASTM E 2445 standards and should be performed periodically to ensure proper and accurate system operation. For easy use of the CR Phantom, a test procedure and the D-Tect Viewer software are available for free download.

To meet the requirements of these standards, the DÜRR NDT CR Phantom includes two duplex wire-type IQIs and measuring points for shading correction positioned in both axis directions (horizontal and vertical). This allows all the required information to be mapped on the imaging plate with a single X-ray exposure – the CR Phantom does not need to be rotated to obtain the data of the second axis, resulting in more accurate test scores and significant time savings.

  • T-target (brass)
    Laser beam jitter, MTF check, blooming (flare)
  • Duplex wire-type IQI 15D (hi-res)
    Basic Spatial Resolution (unsharpness)
  • BAM snail
    Central beam alignment
  • Line pair IQI type 53-b
    Line pair resolution
  • Measuring points
    Shading correction
  • Cassette positioning locator
    Positioning of cassette (imaging plate)
  • Homogeneous strip (aluminum)
    Scanner slippage, scanner shading
  • Lucite plate
    Carrier plate
  • cm/inch ruler
    Linearity check
  • Contrast sensitivity gauge
    Contrast sensitivity check
CR Phantom test specimen

CR Phantom in lined wooden case

CR Phantom test procedure

CR Phantom Long-Term Stability Test Procedure
Register now and download from My DÜRR NDT
www.duerr-ndt.com/register

Computed Radiography Products

HD-CR 35 NDT imaging plate scanner
HD-CR 35 NDT imaging plate scanner

HD-CR 35 NDT

High resolution Computed Radiography imaging plate scanner for all NDT radiography applications - weld testing, profile images and aerospace.

Computed Radiography Imaging Plates
CR Imaging Plates

Imaging Plates

IPs are available in different resolutions and all standard formats and, on request, in special sizes and custom shapes.

D-Tect NDT X-ray inspection software
D-Tect NDT X-ray inspection software

D-Tect X-ray Inspection Software

All functions from image acquisition, image evaluation and report generation to data import and export are included.

© DÜRR NDT GmbH & Co. KG - All rights reserved.